RAMP HEATING

DESCRIPTION

To keep your entrance and exit slopes free of snow and ice, we offer a global solution based on constant wattage heating cables, poured in the concrete or asphalt layer. Based on your plans, we work out the most…

ADVANTAGES

Since 1963 experience with the installation of this system.
Maintenance free.
Extremely reliable solution with long durability.

PROJECTS

 WALK WAY TO ATM AND DRIVE WAY TO UNDERGROUND GARAGE SNOW AND ICE-FREE
IR THERMOGRAPHY OF DRIVEWAY…

DESCRIPTION

Constant wattage slope heating

To keep your entrance and exit slopes free of snow and ice, we offer a global solution based on constant wattage heating cables, poured in the concrete or asphalt layer. Based on your plans, we work out the most optimal solution, comprising heating cables, control panel with regulation, mounting, commissioning and documentation.

As regulation, we foresee a snow- and ice sensor which reacts when it’s both cold and moist. An additional limiter in the concrete or asphalt prevents your system from staying unnecessarily activated.

Our experienced mechanics secure the heating cables on a galvanized netting that’s to be placed on the reinforcement steel. They connect the cold leads into the control panel. Everything is being programmed, measured and commissioned.

 

ADVANTAGES

You receive a documentation package consisting of

  •  Since 1963 experience with the installation of this system.
  • Maintenance free.
  • Fully autonomous system.
  • Fault localization and local repair possible in case of damage.
  • Possible communication with building management system.
  • Extremely reliable solution with long durability.
  • The wattage remains constant in time, compared to self-regulating cables which lose power by aging.
  • Energy saving thanks to limiter.
  • Continuous display “READY” in control panel.
  • Customization possible.

PROJECTS

TECHNICAL SPECIFICATIONS

Technical specifications in concrete

Surface load 300W/m²
Load 30W/m cable
Construction cable (SiPCP) constant wattage single core
– Resistance wire
-Silicone jacket
-PVC inner sheath
-Copper braid
-PVC outer jacket
Circuit length to maximum 230m
Ohmic values: 0,1 to 8 Ohm/m
Nominal tension max 500V
Embedment depth: 50 to 80 mm under upper surface

Technical specifications in asphalt

Surface load 300W /m²
Load 60W/m cable
Construction cable (MI) constant wattage single core
-Resistance wire
-Magnesium Oxide insulation
-Copper inner jacket
-HDPE outer jacket
Circuit length to maximum 138m
Ohmic values: 0,14 to 2 Ohm/m
Nominal tension max 600V
Embedment depth: 30 to 80 mm under upper surface

EXTRA

Control panel

The IP54 control panel is completely pre assembled with the necessary protections and switches per circuit.

Snow and Ice Sensor

This snow and ice sensor can be programmed with for instance moist and temperature sensitivity. He is installed in the slope, leveled with the upper surface

Limiter

The temperature limiter with sensor in the concrete/asphalt, will prevent unnecessary energy consumption by switching off the system at a floor temperature of for instance 5°C.